MINIMUM RECOMMENDED CRITERIA FOR SATISFACTORY CARPET CUSHION PERFORMANCE IN CONTRACT INSTALLATIONS
To help you compare various types of cushion, the Carpet Cushion Council has established recommended minimum contract cushion criteria for three levels of traffic. Any cushion type and grade certified as meeting CCC's guidelines for cushion being installed at a particular traffic level can be expected to perform satisfactorily at that level under normal conditions, when used with a carpet made for the same specified traffic. Red Label: Commercial - Moderate Traffic; Green Label: Commercial - Heavy Traffic; Blue Label: Commercial - Extra Heavy Traffic.
TYPES OF CUSHION | CLASS I - MODERATE TRAFFIC | CLASS II - HEAVY TRAFFIC | CLASS III - EXTRA HEAVY TRAFFIC | ||||||||||||||||
Commercial
Application
Minimum recommended criteria for satisfactory carpet cushion performance in contract installations |
Office Buildings:
Executive or private offices, conference rooms Health Care: Executive, administrative Schools: Administration Airports: Administration Retail: Windows and display areas Banks: Executive areas Hotels/Motels: Sleeping rooms Libraries/Museums: Administration |
Office Buildings: Clerical
areas, corridors (moderate traffic) Health Care: Patients' rooms, lounges Schools: Dormitories and classrooms Retail: Minor aisles, boutiques, specialty Banks: Lobbies, corridors (moderate traffic) Hotels/Motels: Corridors Libraries/Museums Public areas (moderate traffic) Convention Centers: Auditoriums |
Office Buildings:
Corridors (heavy traffic), cafeterias Health care: Lobbies, corridors, nurses' stations Schools: Corridors, cafeterias Airports: Corridors, public areas, ticketing areas Retail: Major aisles, check outs, supermarkets Banks: Corridors (heavy traffic), teller windows Hotels/Motels: Lobbies and public areas Libraries/Museums: Public Areas Country Clubs: Locker rooms, pro shops, dining areas Convention Centers: Corridors and lobbies Restaurants: Dining areas and lobbies | ||||||||||||||||
|
|
|
| ||||||||||||||||
|
|
|
| ||||||||||||||||
|
|
|
|
Footnotes: | Maximum thickness for any product is 3/8" | All thicknesses, weights and densities allow a -5% manufacturing tolerance | |
D - Denotes Density in lbs./cu. ft. | * = Polymer densities | ||
Oz. - Denotes weight in ounces/sq. yd. | ** = Particle size not to exceed 1/2" | ||
CR - Denotes Compression Resistance in lbs./sq. in. as measured by ASTM D-3676 | *** = Ash content = 50% max. | ||
CFD - Denotes Compression Force Deflection as measured by ASTM D-3574 |